BNDCC - K120 RESIN
- MSDS: BNDCC
- Manufacturer: K POXY
- Product Name: K120 RESIN
- National Stock Number: 8040-00N029173
Product Identification
Product ID:K120 RESIN
MSDS Date:05/03/1990
FSC:8040
NIIN:00N029173
MSDS Number: BNDCC
Responsible Party
WALTHAM, MA 02254
US
Emergency Phone: 617-647-5560
Info Phone: 617-647-5560
Preparer: H. JAMES WHITE
Cage: 47078
Contractor
Telephone: 617-647-5560
Cage: 47078
Ingredients
EPICHLOROHYDRIN BIS-PHENOL A; (BISPHENOL A/EPICHLOROHYDRIN)
CAS: 25068-38-6
RTECS: SL6475000
Fraction By Weight: <25%
PHENOL-FORMALDEHYDE POLYMER, GLYCIDYL ETHER
CAS: 28064-14-4
Fraction By Weight: <5%
SILICON DIOXIDE, AMORPHOUS; (FUMED SILICA)
CAS: 7631-86-9
Fraction By Weight: <2%
OSHA PEL 6 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
IRON POWDER
CAS: 65997-19-5
Fraction By Weight: >65%
TALC, CALIFORNIA (MICROTALC, TALCRON, CERCRON); (MICROTALC)
CAS: 14801-96-6
Fraction By Weight: <3%
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGEST:NO SPECIFIC INFORMATION.
SLIGHTLY TOXIC. INHAL:HEATED VAPORS MAY CAUSE RESPIRATORY
IRRITATION. SKIN:MILDLY IRRITATION TO THE SKIN. MAY CAUSE ALLERGIC
REACTION EVIDENCED BY RASHES. EYE:MODERATEL Y IRRITATING TO THE
EYES. PROLONGED CONTACT WITH THE SKIN MAY RESULT IN SKIN IRRITATION
AND DERMATITIS.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:PRE-EXISTING EYE, SKIN &
RESPIRATORY DISORDERS MAY BE AGGRAVATED BY EXPOSURE TO THIS
PRODUCT. PRE-EXISTING SKIN OR LUNG ALLERGIES MAY INCREASE CHANCE OF
DEVELOPING INCREASED ALLERGY SYMPTOMS.
First Aid
First Aid:EYE:FLUSH W/PLENTY OF H2O FOR AT LEAST 15 MIN & SEEK IMMED MD
ATTN. SKIN:REMOVE CONTAM CLTHG BEFORE REUSE & DISCARD CONTAM
LEATHER ARTICLES. GET MD ATTEN IF SWELLING/REDDENING OCCURS.
INGEST: IF APPRE CIABLE QTY ARE SWALLOWED, SEEK MD ATTEN. DO NOT
INDUCE VOM. DILUTE BY GIVING H2O/MILK TO DRINK IF VICTIM IS
CONSICIOUS. INHAL:IN CASE OF EXPOS TO HIGH CONC OF VAP/MIST, REMOVE
PERSON TO (SUPP DATA)
Fire Fighting
Flash Point Method:PMCC
Flash Point:>450F,>232C
Extinguishing Media:USE CARBON DIOXIDE OR DRY CHEMICAL FOR SMALL FIRES:
AQUEOUS FOAM OR WATER FOR LARGE FIRES.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . REMOVE ALL IGNITION SOURCES. USE A WATER
SPRAY TO COOL FIRE EXPOSED CONTAINERS.
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY RUPTURE (DUE TO
BUILDUP OF PRESSURE) WHEN EXPOSED TO EXTREME HEAT. TOXIC FUMES WILL
BE EVOLVED IF THIS MATERIAL BURNS.
Accidental Release
Spill Release Procedures:DIKE SPILL. ABSORB WITH INERT MATERIAL AND
COLLECT FOR DISPOSAL. FLUSH AREA WITH WATER. PREVENT WASHINGS FROM
ENTERING WATERWAYS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:AVOID CONTAMINATION OF SKIN. REMOVE
AND THOROUGHLY LAUNDER CONTAMINATED CLOTHING BEFORE REUSE. DISCARD
CONTAMINATED SHOES.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:WEAR A PROPERLY FITTED NIOSH/MSHA APPROVED
RESPIRATOR WHENEVER EXPOSURE TO VAPOR/MIST IS LIKELY UNLESS LEVELS
ARE BELOW APPLICABLE LIMITS.
Ventilation:LOCAL EXHAUST-REC WHEN APPROP TO CONTROL EMPLOYEE EXPOS.
MECH-NOT REC AS SOLE MEANS OF CONTROLLING EMPLOYEE EXPOSURE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:FOR OPERATIONS WHERE CONTACT CAN OCCUR,
COVERALLS/APRON & RUB FOOT COVERING ARE REC. SAFETY SHOWER & EYE
(SUPP DATA)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRST AID:FRESH AIR. GET MD ATTENTION IF EFFECTS PERSIST. ADMINISTER
OXYGEN IF NECESSARY. OTHER PROT EQUIP:WASH FACILITY SHOULD BE
AVAILABLE.
Chemical Properties
HCC:N1
Vapor Pres:<1
Vapor Density:>1
Spec Gravity:3.11
Solubility in Water:NIL
Appearance and Odor:BLACK PASTE. NO DISTINCTIVE ODOR.
Percent Volatiles by Volume:NEG
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS & MINERAL ACIDS. UNCONTROLLED CURING W/AMINE
CURING AGENTS IN MASSES >2 INCHES THICK.
Stability Condition to Avoid:EXCESSIVE HEAT.
Hazardous Decomposition Products:FUMES PRODUCED WHEN HEATED TO
DECOMPOSITION MAY INCLUDE:CO, CO2, ALDEHYDES AND ACIDS.
Disposal
Waste Disposal Methods:INCINERATE OR USE BIOLOGICAL TREATMENT IN
ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.